Our Products

.

Key Features:

  • High Accuracy
         -  Volts & Amps: + 1.0% of reading
         -  Frequency:    + 0.2
  • Bright Red LED display of 14mm height
  • Smart Elegant Industrial look
  • Intuitive Dual function key
  • Bright LED indicators - Kilo & Phase indication for measured value. 

Specifications:

 

Unique  DM1110
1 Ø A
DM3110
3 Ø A 
DM1210
1 Ø V 
DM3210
3 Ø V 
DM1310
1 Ø F 
Universal
Ranges
50mA – 60A
45-65 Hz
44 – 480Vac
45-65 Hz
44 – 480VLL
45-65 Hz
20 to 100 Hz
44 to 480 Vac
Wide Range
Control Supply 
90 to 300 Vac
 Low Burden Aux < 3 VA at 240 V
User Programmable  CT Ratio PT Ratio Auto 
 Auto Scaling A to KA V to KV 20 to 100Hz

 

Rugged Construction:

  • Emission                :  CISPR22
  • Fast Transient       :  4 kV IEC 61000-4-4
  • Surge withstand    : 4 kV IEC 61000-4-5
  • ESD                        : 15 kV Air discharge, 8 kV contact discharge
                                      IEC 61000-4-2
  • Impulse voltage      :  6 kV,1.2/50 μSecond, IEC 60060
  • Safety                    :  Self extinguishable V0 plastics
                                      Measurement category III
                                      Pollution degree 2
                                      Spacing & Isolation as per UL & IEC Standards
  • Sealed-dust proof
    construction
  • Temperature
  • Operating               :  -10 °C to 60 °C (14 °F to 140 °F)
  • Storage                  :  -25 °C to 70 °C (-13 °F to 158 °F)
  • Weight                    :  400 gms approx, Unpacked;
                                      500 gms approx, Shipping
  • Panel cut out          :  92 x 92 mm Flush mount

Applications:

  • 1 & 3 ph AC Volts & Amps and 1 ph Hz measurement & Monitoring
  • 3 Phase Volts & Hz monitoring with selector switch (DM1000 series)
  • Electrical load monitoring
  • Gensets, Test benches & Laboratories
  • Capacitor rated current measurement in PFI panels





The PowerLogic ION7300 series meters offer unmatched value, functionality, and ease of use. Used in energy management applications such as feeder monitoring and sub-metering, PowerLogic ION7300 series meters interface with power monitoring software or other energy management or automation systems to provide users with real-time information for monitoring and analysis.
  
A choice of feature sets is offered through two models:

  • ION7330 has the following features: analog I/O, digital I/O, two RS-485 ports, web server (Ethernet option only), modem, gateways, email (Ethernet option only), event logging, min/max logging, 32-channel historical logging, setpoints, harmonics measurement (to 15th).
  • ION7350 adds the follwoing additional features: 96-channels of historical logging, dip/swell monitoring, harmonics measurement to 31st, waveform capture, and call-out on alarm.

Characteristics (some features are optional):

  • Panel-mount, LCD display, available without display
  • 3-phase, 4-quadrant metering, class 0.5 revenue-accurate (IEC & ANSI)
  • Voltage, current, power, frequency, power factor, demand, energy, and time-of-use metering
  • 64 samples/cycle waveform capture, dip/swell monitoring, harmonics measurement (up to 31st)
  • Sequence-of-events, coincident minimum/maximum, historical trends, and high-speed snapshot recording, 1 ms resolution timestamping
  • 4 analogue inputs, 4 analogue outputs, 4 digital status/counter inputs, 4 digital control/pulse outputs
  • 12 setpoints for alarms and control, 1 second response, multi-condition, call out on alarm
  • 5 communication ports: Ethernet, modem, 2 x RS-485, RS-485, front panel optical
  • Protocols: Modbus RTU slave, Modbus TCP, DNP 3.0, MV-90
  • Ethernet and modem gateways to 31 devices on RS-485 port
  • On-board web server, email for alarms and data logs 
     
Benefits
The PowerLogic ION7300 series meters help you:
  • reduce energy and operations costs
  • improve power quality, reliability and uptime
  • optimise equipment use for optimal management of your electrical installation and greater productivity
Applications
  • Analysis of efficiency, losses and capacity
  • Cost allocation and sub-metering
  • Power quality monitoring
  • Problem notification and diagnosis
  • Demand or power factor management 















The PowerLogic ION7550 and ION7650 each have a different feature set:

  • ION7550: revenue-class power and energy metering, event and min/max logging, historical logging (up to 800 channels), expandable memory, sag/swell monitoring, harmonics measurement, waveform capture at 256 samples/cycle, setpoints, digital and analogue I/O, and Internet-enabled multi-port communications
  • ION7650: adds symmetrical components measurement, fast transient detection, waveform capture at 1024 samples/cycle, and power quality compliance monitoring.
Characteristics (some features are optional):
  • Panel-mount, large customisable LCD display, available without display
  • Multilingual support for English, French, Spanish and Russian. User-configurable IEC or IEEE notations. 12/24 hour clock support in multiple date/time formats.
  • 3-phase, 4-quadrant metering, class 0.2 accuracy (IEC, ANSI)
  • Voltage, current, neutral and earth current, power, frequency, power factor, demand, energy, and time-of-use metering
  • Instrument transformer correction, transformer/line loss compensation
  • IEC 61000-4-30 class A ed. 2, IEEE 519/1159, EN50160, IEC 61000-4-7/4-15 power quality compliance monitoring
  • 1024 samples/cycle waveform capture, transient capture (20 μs @ 50 Hz), sag/swell monitoring, harmonics measurement (up to 63rd), symmetrical components
  • COMTRADE waveform format available directly from the meter
  • Disturbance direction detection to indicate whether a disturbance originated upstream or downstream from the meter
  • Setpoint learning to automatically learn what constitutes a sag, swell, transient or high and low setpoint
  • Sequence-of-events, coincident minimum/maximum, historical trends, and high-speed snapshot recording, 1 ms resolution timestamping, GPS time synchronisation
  • 4 analogue inputs, 4 analogue outputs, 16 digital status/counter inputs, 7 digital control/pulse outputs
  • 65 setpoints for alarms and control, 1/2 cycle response, multi-condition, call out on alarm
  • 5 communication ports: Ethernet, modem, RS-232/485, RS-485, front panel optical
  • 100Base–TX and 100Base–FX for faster Ethernet communication
  • Protocols: Modbus RTU slave/master, Modbus TCP, DNP 3.0, MV-90, IEC 61850
  • Ethernet and modem gateways to 31 devices on RS-485 port
  • On-board web server, email for alarms and data, FTP server
Benefits

The PowerLogic ION7650/ION7550 meters help you:

  • reduce energy and operations costs
  • improve power quality, reliability and uptime
  • optimise equipment use
    for optimal management of your electrical installation and greater productivity.
Applications
  • Analysis of efficiency, losses and capacity
  • Bill verification, cost allocation and sub-metering
  • Power quality compliance monitoring
  • Problem notification and diagnosis
  • Demand or power factor management
  • Control of loads, generators or other equipment 













Leading the way in smart grid utility metering, the high-accuracy PowerLogic ION8600 meter is the premium socket / switchboard meter for grid revenue, power quality, and substation automation applications.

There are three different meter models to suit your needs according to features and functionality:

  • PowerLogic ION8600 for revenue metering
  • PowerLogic ION8600 for revenue metering and power quality compliance monitoring
  • PowerLogic ION8600 for revenue metering and advanced power quality analysis
Characteristics

  • High accuracy, single current range (2 times more accurate than existing ANSI/IEC Class 0.2 standards from 0.010A-20A)
  • IEC 61850 protocol including COMTRADE support
  • IEC 61000-4-30 Class A/S power quality measurement method
  • Power quality compliance monitoring of international quality-of-supply standards (IEEE 519, EN50160, IEC 61000-4-7, IEC 61000-4-15, CBEMA/ITIC)
  • Increased onboard memory – ION8650A/B/C (128Mb/64Mb/32Mb)
  • 1024 samples/cycle measurements for all voltage/current channels
  • Dual simultaneous low (32 samples/cycle) and high resolution (1024 samples/cycle) voltage waveform capture
  • Up to 5 simultaneous communicating ports (*Limited to 3 ports on C model): Ethernet, modem, RS-232/485, RS-485, front ANSI optical port
  • User selectable industry standard protocols available through serial and Ethernet including: Itron MV-90, Modbus, Modbus Master, DNP 3.0 and IEC 61850.
  • User customizable register maps for Modbus and DNP protocols
  • Ethernet and modem gateway for up to31 devices on each RS-485 port
  • On-board web server, email alarms and data logs
  • Easily integrate with PowerLogic ION Enterprise operations software or other energy management systems












The PowerLogic ION8800 meters are rack-mount meters for utility network monitoring. They are available in three different base models:

  • The ION8800A is an energy/tariff meter with EN50160 compliance monitoring, waveform capture, and transient detection.
  • The ION8800B is an energy/tariff meter with EN50160 compliance monitoring.
  • The ION8800C is a basic energy/tariff meter.
     
Characteristics

  • DIN 43862 (19-inch rack mount) IEC standard for easy retrofit into existing systems
  • Essailec connector with common measurement and energy pulsing pin-out
  • High-accuracy metering in compliance with IEC 62053-22 Class 0.2S
  • IEC 61000-4-30 Class A power quality measurement method
  • Power quality compliance monitoring of international quality-of-supply standards (IEEE 519, EN50160, IEC 61000-4-7, IEC 61000-4-15, CBEMA/ITIC)
  • Detection and capture of dips and swells
  • Waveform recording at 1024 samples/cycle; 20 µs transient capture
  • Inter-harmonics measurements (ION8800A)
  • 24 setpoints for single/multi-condition alarms and control functions with 1 second response
  • Communication module supports: fibre, Ethernet, modem, RS-232/485, RS-485
  • Protocol support for Modbus RTU slave/master, Modbus TCP slave/master, DNP 3.0, MV-90, DLMS
  • Ethernet and modem gateways to 31 devices on RS-485 port
  • High-speed Ethernet communications (optional) with on-board web server
  • Email for sending data logs and alarm notification
  • Multiple tariffs and time-of-use
Benefits

  • Reduce operations costs
  • Improve power quality
  • Improve continuity of service
Applications
  • Transmission and distribution metering
  • Revenue metering
  • Extensive power quality monitoring and analysis
  • Power quality compliance monitoring
  • Digital fault recording
  • Instrument transformer correction













Features:

                EM6459

  • Global : UL, C UL Listed, CE, C-Tick certified
  • Accuracy Class 1.0 (0.55 & 0.2S Optional)
  • True RMS, Accurate on Distorted waveforms
  • Simultaneous sampling of Volts & Amps
  • Low PT, CT burden
  • Wide range of Auxiliary Supply (Control Power)
  • Programmable CT, PT rations
  • Built-in phase analyzer
  • Quick and easy installation
  • Auto Scrolling
  • 10 year back-up of integrated data.
  • Turbo Key for One Touch operation and setup
  • Measures 4 Quadrant Power & 2 Quadrant Energy (IE Optional measures 4 Quadrant Energy in EM6400)
  • CT reversal : Auto-correction for Energy integration in star (wye) mode
  • Demand Monitoring (Optional)













meetering
1. In SETUP mode, press until METER is visible
2. Press METER.
3. Press until SYS (sytem type) is visible.
4. Press SYS.
5. Select your system type based on the (A) number
of wires. (B) number of CTs, (C) the number of
volatage connections (either direct connect or with
PT), and (D) the SMS system type.
6. Press OK.
7. Press until you are asked to save your changes.
8. Press YES to save the changes.
Setup Meter System Type
1. Press uuntil COMMS (communications) is visible.
2. Press COMM1 (communications).
3. Select the protocol: MB.RTU (Modbus RTU). Jbus,
MB, A.8 (Modbus ASCII 8 bits), MB, A.7
(Modbus ASCII 7 bits).
4. Press OK.
5. Enter the ADDR (power meter address).
6. Press OK.
7. Select the BAUD (baud rate).
8. Press OK.
9. Select the parity: EVEN, ODD, or NON.
10. Press OK.
11. Press until you are asked to save your changes.
12. Press YES to save the changes.
Power Meter With Remote
Display Communications Setup:
1. Press uuntil METER is visible
2. Press METER.
3. Press PT.
4. Enter the SCALE value: x1, x10, x100.
No PT (for direct connect).
5. Press OK
6. Enter the PRIM (primary CT) value.
7. Press OK
8. Enter the SEC. (secondary CT) value.
9. Press OK.
10. Press until you are asked to save
your changes.
11. Press YES to save the changes.
Setup PT Ratio:
1. Press uuntil METER is visible
2. Press METER.
3. Press CT.
4. Enter the PRIM (primary CT) number.
5. Press OK
6. Enter the SEC. (secondary CT) number.
7. Press OK
8. Press until you are asked to save your changes
9. Press YES to save the changes.
Setup CT Ratio:
1. Press uuntil COMMS
(communications) is visible.
2. Press COMM2 (communications).
3. Select the protocol: MB.RTU (Modbus RTU).
Jbus, MB, A.8 (Modbus ASCII 8 bits),
MB, A.7 (Modbus ASCII 7 bits).
4. Press OK.
5. Enter the ADDR (power meter address).
6. Press OK.
7. Select the BAUD (baud rate).
8. Press OK.
9. Select the parity: EVEN, ODD, or NON.
10. Press OK.
11. Press until you are asked to
save your changes.
12. Press YES to save the changes.
Comm2 Setup:
1. Press uuntil COMMS (communications) is visible.
2. Press COMMS (communications).
3. Select the protocol: MB.RTU (Modbus RTU). Jbus,
MB, A.8 (Modbus ASCII 8 bits), MB, A.7
(Modbus ASCII 7 bits).
4. Press OK.
5. Enter the ADDR (power meter address).
6. Press OK.
7. Select the BAUD (baud rate).
8. Press OK.
9. Select the parity: EVEN, ODD, or NON.
10. Press OK.
11. Press until you are asked to save your changes.
12. Press YES to save the changes.
Power Meter With Integrated
Display Communications Setup:













EM 6400 Digit AN EM6433, EM6436, EM6434


Features:


  • Global : UL, C UL Listed, CE, C-Tick certified
  • Accuracy Class 1.0 (0.55 & 0.2S Optional)
  • True RMS, Accurate on Distorted waveforms
  • Simultaneous sampling of Volts & Amps
  • Low PT, CT burden
  • Wide range of Auxiliary Supply (Control Power)
  • Programmable CT, PT rations
  • Built-in phase analyzer
  • Quick and easy installation
  • Auto Scrolling
  • Communication with PCs, PLCs, DCS through RS 485 Serial Port (Built-in for EM 6434 & EM 6433 and optional for EM6436, EM 6400)
  • 10 year back-up of integrated data.
  • Turbo Key for One Touch operation and setup
  • Measures 4 Quadrant Power & 2 Quadrant Energy (IE Optional measures 4 Quadrant Energy in EM6400)
  • CT reversal : Auto-correction for Energy integration in star (wye) mode
  • Demand Monitoring (Optional)
  • PF per phase and 3 phase
  • Sealed dust – proof construction
  • Touch safe terminals
  • Easy set up through Front Panel keys
  • Keypad lock


EM 6434


  • Displays all power and energy parameters, Run hours, ON hours & number of pwer interruption
  • Monitors loading characteristics of motors


EM 6433


  • Monitors active/apparent power & energy consumption, load current, Run hours, ON hours in a single meter.
  • Displays Amps, Power simultaneously.















Characteristics :

  • True RMS, CT PT operated
  • Compact 96 x 96 mm size
  • Low PT, CT burden
  • Accuracy class 1.0 IEC 61036 & Class 0.5
  • Simultaneous sampling of Volts & Amps
  • Accurate on distorted waveforms
  • Sealed dust-proof construction
  • Quick and easy installation
  • Reverse LED for trouble shooting
  • Tamper proof cover option
  • 3 phase 4 wire (& Single phase) - model DM5240
  • 3 Phase 3 wire - DM5230
  • Industrial quality
Benefits

Electronic kWh meter

  • kWh monitoring in all electrical panels.
  • Isolated pulse output to drive remote counter, PLC, DCS station for offline monitoring of energy data, online control for energy/power/process optimization
  • Field settable standard full scale
Applications
  • Electrical Panels
  • Test Benches
  • Wind Energy
  • Co-Generation
  • Genset Panels
  • Lab Equipment
  • Power Plants
  • All types of Industries
  • Load Centers








  • Universal whole current 2.5A, 5A & 10A Ib
  • Equivalent of 7 digits display
  • Accuracy class 1.0 as per IEC61036, CBIP 88
  • Tamper Indication : Current reversal, Earthed load tamper
  • Pulse output option for online Energy Billing Systems
  • Accurate Billing due to higher least count of register
  • Built-in transient protection
Benefits

Single Phase Tariff Energy Meter

  • Minimises Power Loss due to low VA burden
  • Prevents unauthorised utilization of power
  • Prevents tampering
Applications
  • Energy Billing
         o Shopping Malls
         o Small scale industries
         o Residential Buildings











-AUTO SCALIN ;KILO -MEGA-GIGA

-TRUE RMS & INTEGRATED LIKE V,A,F. UNBALANEC IN PHASES (%),RPM*

Schneider-EFL 3234**EFL3234

Dual Source Energy Meter:

Schneider-EM 6438 Energy Meter

Dual Source Energy Meter:
EM6438 & EM6436 Dual
1 Digital meter with analog indicator
Two Energy Registers (U and G) separately record consumption based on a
Control Signal for Dual Source energy billing.



1 Digital meter with analog indicator
Two Energy Registers (U and G) separately record consumption based on a
Control Signal









-EM6433
-EM6434
-EM6436
-EM6400











Encompassing all aspects of power quality – from impulsive voltage transients to flicker – with industry-leading measurement accuracy, the CM4000T and CM4250 have embedded high-tech features including extremely high accuracy, copious memory, and built in analytical tools..

Designed specifically for critical power users and large energy consumers, Series 4000 Circuit Monitors are more than just advanced power quality monitors; they are also highly accurate energy monitors with the ability to monitor electricity and other utilities including gas, compressed air, water, and steam. Plus you can access information using your web browser!

Features

  •  Web-enabled access to information – HTML pages let you easily view information using a standard web browser (with optional Ethernet card).
  • Email on alarm – Provides immediate notification of problems for fast correction. Customizable schedules to ensure that the correct personnel are notified.
  • Extensive onboard memory – 16 MB of standard onboard memory (expandable to 32 MB) captures billing data and consumption trends without data gaps, events and waveforms. Fourteen log files include individually configurable quantities and recording intervals.
  • Power quality summary – Combines each power quality category into a single index to indicate the general level of power quality at the metering point.
  • Disturbance direction detection – Indicates upstream or downstream occurrence to locate the source of a disturbance in relation to the meter plus provides a level of confidence..
  • Harmonic power flows – Meters at the point of common coupling measure harmonic power flow to help determine whether harmonic currents originated inside the facility or out on the utility grid.
  • Impulsive transient detection (CM4000T) – Capture extremely short duration (200 nanosecond) voltage events to determine their source. Verify the adequacy of transient mitigation equipment.
  • Flicker measurement (CM4000T) – Measures voltage flicker according to IEC standards. Use for determining the level of flicker due to internal and external influences.
  • Anomaly evaluations based on the latest IEEE and IEC – Power quality standards including IEC 61000-4-7, IEC 61000-4-15, IEC 61000-4-30, IEEE 1159, IEEE 519, IEEE 153, and EN 50160.
  • Higher sampling rate – Means greater ability to detect short duration and steady state power quality problems.
  • Waveform capture – To the 255th harmonic allows you to find the toughest power problems.
  • Flexible I/O for pulse counting – Shift energy logging, energy trending and forecasting are just a few of the features designed to help you manage and reduce total energy costs.
  • Modular design and downloadable firmware – Increases technological longevity allowing incremental expansions and functionality enhancements into the c


Main
Range of product Vigilohm
Device short name IM10
Product or component
type
Insulation monitoring device
Device application Medium network
Photovoltaic
Earthing system IT
Language Chinese
English
French
German
Italian
Portuguese
Russian
Spanish
Complementary
Type of installation to be monitored <= 345 V - DC
<= 480 V - AC at 45...440 Hz ( device connected to phase )
<= 600 V - AC at 45...440 Hz ( device connected to neutral )
Type of measurement Network insulation resistance : 0.1 kOhm...10 MOhm
Local signalling Orange flashing indicator light : transient fault
Orange indicator light : below fault threshold
White indicator light : below prevention threshold
Green indicator light : satisfactory insulation resistance
Threshold setting Fault : 0.5...500 kOhm
Prevent : 1 kOhm...1 MOhm
Time delay Signalling circuit : 0...300 s
Response time <= 5 s
Auxiliary supply voltage 125...250 V - DC +/- 15 %
110...415 V - AC at 45...440 Hz +/- 15 %
Power consumption 12 VA
Measurement voltage 75 V
Measurement current < 0.4 mA
Internal impedance 110 kOhm - AC at 0.1...440 Hz
Test function Manual
Self test
Output contact 1 C/O standard or fail-safe
Breaking capacity 12...24 V - DC at 6 A
250 V - AC at 6 A
Display type Digital
Mounting mode Flush mounting
Mounting support DIN rail
Panel
Auxiliary connection terminal Removable screw terminal block : 0.2...2.5 mm²
Material Thermoplastic
Overvoltage category III
Product weight 0.25 kg
Height 110 mm
Width 96 mm
Depth 59 mm


Environment
Dielectric strength 5500 V - DC
4000 V - AC
IP degree of protection Front face : IP52
Environmental characteristic Salt mist conforming to IEC 60068-2-52
Exposure to damp heat in service conforming to IEC 60068-2-56
Exposure to damp heat not in service conforming to IEC 60068-2-30
Operating altitude <= 3000 m
Pollution degree 2
Standards IEC 61010-1
IEC 61557-8
IEC 60364-4-41
Product certifications DNV
Ambient air temperature for operation -25...55 °C
Ambient air temperature for storage -40...70 °C
Offer Sustainability
Sustainable offer status Not Green Premium product
RoHS Compliant - since 1028 - Schneider Electric declaration of conformity
Product environmental profile Available
Product end of life instructions Available